Generators
5500
Watt Gasoline 6000
Watt Two Bearing 6000
Watt Gasoline 6000
Watt Diesel
10000 Watt Two Bearing
10000 Watt Gasoline
15000 Watt PTO
15000 Watt
Gasoline
All Gasoline Units Available as Propane/Natural Gas
| 5500 Watt Gasoline (Propane/Natural Gas Available) | ||
| Models:
|
*LR55R (Recoil Start) (Gasoline) *LR55R/LP (Recoil Start) (Propane/Natural Gas) *LR55RE (Electric & Recoil Start) (Gasoline) *LR55RE/LP (Electric & Recoil Start) (Propane/Natural Gas) |
|
| Wattage: | 5500 Watts Surge, 4500 Watts Continuous, 1 phase, 60Hz @ 3600 RPM | |
| Amps: | 37.5 Amps @ 120 Volts, 18.8 Amps @ 240 Volts | |
| Features: |
Totally Brushless Design with Capacitor All Copper Windings Voltage Plus, <6% Distortion Exclusive Smooth Wave Voltmeter Hour Meter Easy Idle with Delay Circuit Full Power Switch at 120 Volts & 240 Volts Circuit Breaker Protector for Each Receptacle |
|
| Fuel Tank: | 5 U.S. Gallons | |
| Run Time: (Gasoline) |
1/2 Load = 10.9 Hours Full Load = 7.6 Hours |
|
| Engine: | 9 HP Subaru/Robin, OHV, Cast Iron Cylinder Liner, Solid State Ignition, Low Oil Shutdown, Low Tone Muffler | |
| Receptacles: |
1-20amp, 120 Volt, GFI NEMA, 5-20R (2 Outlets, 1
Duplex) 1-30amp, 120 Volt, Twistlock, NEMA l5-30R Circuit Breaker Protector for Each Receptacle |
|
| Frame: | 1" Welded Steel Roll Cage Frame with Isolated Recessed Control Panel | |
|
Dimensions |
|||
| Length | Width | Height | Weight |
| 28" | 22" | 25" | 152 lbs. |
| 6000 Watt Two Bearing Generator | ||
| Model: | AB60 | |
| Wattage: | 6000 Watts Surge, 5000 Watts Continuous, 1 phase, 60Hz @ 3600 RPM | |
| Amps: | 41.6 Amps @ 120 Volts, 20.8 Amps @ 240 Volts | |
| Features: |
Totally Brushless Design with Capacitor All Copper Windings Voltage Plus, <6%-9% Distortion Exclusive Smooth Wave Voltmeter Circuit Breakers |
|
| Minimum Required Engine HP: |
11 |
|
| Shaft Diameter: | .875" | |
| Keyway: | .1875" | |
| Required Pulley: (Not Supplied) |
Single |
|
| Shaft Rotation From PTO View: |
Bi-Directional |
|
| Receptacles: |
1-120 Volt, Duplex 20A, 5-20R 1-240 Volt, 20A, L14-20R Circuit Breaker |
|
|
Dimensions |
|||
| Length | Width | Height | Weight |
| 16" | 7.125" | 7.5" | 49 lbs. |
| 6000 Watt Gasoline (Propane/Natural Gas Available) | ||
| Model: |
LR60H (Recoil Start) (Gasoline) LR60H/LP (Recoil Start) (Propane/Natural Gas) LR60HE (Electric & Recoil Start) ( Gasoline) LR60HE/LP (Electric & Recoil Start) (Propane/Natural Gas) |
|
| Wattage: | 6000 Watts Surge, 5000 Watts Continuous, 1 phase, 60Hz @ 3600 RPM | |
| Amps: | 41.6 Amps @ 120 Volts, 20.8 Amps @ 240 Volts | |
| Features: |
Totally Brushless Design with Capacitor All Copper Windings Voltage Plus, <6% Distortion Exclusive Smooth Wave Voltmeter Hour Meter Easy Idle with Delay Circuit Full Power Switch at 120 Volts & 240 Volts Circuit Breaker Protector for Each Receptacle |
|
| Fuel Tank: | 5 U.S. Gallons | |
| Run Time: (Gasoline) |
1/2 Load = 10.4 Hours Full Load = 7.6 Hours |
|
| Engine: | 11 HP Honda, OHV, Cast Iron Cylinder Liner, Solid State Ignition, Recoil Start, Low Oil Shutdown, Low Tone Muffler | |
| Receptacles: |
1-20amp, 120 Volt, GFI NEMA, 5-20R (2 Outlets, 1
Duplex) 1-30amp, 120 Volt, Twistlock, NEMA L5-30R 1-20amp, 240 Volt, Twistlock, NEMA L14-20R Circuit Breaker Protector for Each Receptacle |
|
| Frame: | 1" Welded Steel Roll Cage Frame with Isolated Recessed Control Panel | |
|
Dimensions |
|||
| Length | Width | Height | Weight |
| 28" | 22" | 25" | 179 lbs. |
| 6000 Watt Diesel | ||
| Model: | LR60EL (Diesel) | |
| Wattage: | 6000 Watts Surge, 5000 Watts Continuous, 1 phase, 60Hz @ 3600 RPM | |
| Amps: | 41.6 Amps @ 120 Volts, 20.8 Amps @ 240 Volts | |
| Features: |
Totally Brushless Design with Capacitor All Copper Windings Voltage Plus, <6% Distortion Exclusive Smooth Wave Voltmeter Hour Meter Full Power Switch at 120 Volts & 240 Volts Circuit Breaker Protector for Each Receptacle |
|
| Fuel Tank: | 5 U.S. Gallons | |
| Run Time: (Diesel) |
1/2 Load = 14.0 Hours Full Load = 10.5 Hours |
|
| Engine: | 10 HP Lombardini, 15LD400, Cast Iron Cylinder Liner, Electric Start | |
| Receptacles: |
1-20amp, 120 Volt, GFI NEMA, 5-20R Straight
Blade 1-30amp, 120 Volt, Twistlock, NEMA L5-30R 1-20amp, 240 Volt, Twistlock, NEMA L14-20R Circuit Breaker Protector for Each Receptacle |
|
| Frame: | 1" Welded Steel Roll Cage Frame with Isolated Recessed Control Panel, Heavy Duty Vibration Isolators | |
|
Dimensions |
|||
| Length | Width | Height | Weight |
| 28" | 22" | 25" | 187 lbs. |
| 10000 Watt Two Bearing Generator | ||
| Model: | AR100 | |
| Wattage: | 10000 Watts Surge, 9500 Watts Continuous, 1 phase, 60Hz @ 3600 RPM | |
| Amps: | 79.2 Amps @ 120 Volts, 39.6 Amps @ 240 Volts | |
| Features: |
Totally Brushless Design with Capacitor All Copper Windings Voltage Plus, <6%-9% Distortion Exclusive Smooth Wave Voltmeter Circuit Breakers |
|
| Minimum Required Engine HP: |
16-18 |
|
| Shaft Diameter: | 1.0" | |
| Keyway: | .25" | |
| Required Pulley: (Not Supplied) |
Double |
|
| Shaft Rotation From PTO View: |
Bi-Directional |
|
| Receptacles:
|
2-120 Volt, Duplex 20A, 5-20R 1-240 Volt, 20A, L5-30R 1-240V T/L 30A, L14-30R 1-240V, 50A, 6-50R Circuit Breaker |
|
|
Dimensions |
|||
| Length | Width | Height | Weight |
| 20.5" | 9.125" | 13.0" | 108 lbs. |
| 10000 Watt Gasoline (Propane/Natural Gas Available) | ||
| Model: | LR105EI (Gasoline) LR105EI/LP (Propane/Natural Gas) |
|
| Wattage: | 10000 Watts Surge, 9500 Watts Continuous, 1 phase, 60Hz @ 3600 RPM | |
| Amps: | 79.2 Amps @ 120 Volts, 39.6 Amps @ 240 Volts | |
| Features: |
Totally Brushless Design with Capacitor All Copper Windings Voltage Plus, <6% Distortion Exclusive Smooth Wave Voltmeter Hour Meter Easy Idle with Delay Circuit Full Power Switch at 120 Volts & 240 Volts Circuit Breaker Protector for Each Receptacle |
|
| Fuel Tank: | 8 U.S. Gallons | |
| Run Time: (Gasoline) |
1/2 Load = 9.0 Hours Full Load = 6.0 Hours |
|
| Engine: | 18 HP Vanguard, OHV, Twin Cylinder, Full
Pressure Lubrication, Oil Cooler and Oil Filter, Low Oil Pressure Shut
Down, Cast Iron Cylinder Liners, Electic Start with Auxiliary Recoil Starter and Low Tone Muffler |
|
| Receptacles: |
2-20amp, 120 Volt, GFI NEMA, 5-20R Straight
Blade with (4 Outlets 2 Duplexes) 1-30amp, 120 Volt, Twistlock, NEMA L5-30R 1-30amp, 240 Volt, Twistlock, NEMA L14-30R 1-50amp, 240 Volt, Twistlock, CS6369 Circuit Breaker Protector for Each Receptacle |
|
| Frame: | 1" Welded Steel Roll Cage Frame with Isolated Recessed Control Panel | |
|
Dimensions |
|||
| Length | Width | Height | Weight |
| 30" | 24" | 25" | 234 lbs. |
| 15000 Watt Tractor Driven PTO Generator | ||
| Model: | PTO15/12 | |
| Wattage: | 15000 Watts Surge, 12000 Watts Continuous, 1 phase, 60Hz @ 3600 RPM | |
| Amps: | 100 Amps @ 120 Volts, 50 Amps @ 240 Volts | |
| Features: |
Totally Brushless Design with Capacitor All Copper Windings Voltage Plus, <6%-9% Distortion Exclusive Smooth Wave Voltmeter Thermal/Magnetic Circuit Breakers PTO Safety Shield Lifting Eye Full Power 240 Volt Plugs/Connectors Included Gear Transmission |
|
| Minimum Required Engine HP: |
24 |
|
| Shaft Diameter: | 1-3/8" 6 Spline | |
| PTO RPM: | 540 | |
| Generator RPM: | 3600 | |
| Max Motor Starting, Code G: |
7.5 |
|
| Receptacles: |
1- 120 Volt, Duplex 20A, 5-20R 1-240 Volt, 30A, L14-30R 1-240V 50A Twistlock CS6369 Circuit Breakers |
|
|
Dimensions |
|||
| Length | Width | Height | Weight |
| 29" | 10.875" | 16" | 186 lbs. |
| 15000 Watt Gasoline (Propane/Natural Gas Available) | ||
| Model: | LR150V (Gasoline) LR150V/LP (Propane/Natural Gas) |
|
| Wattage: | 15000 Watts Surge, 12000 Watts Continuous, 1 phase, 60Hz @ 3600 RPM | |
| Amps: | 100 Amps @ 120 Volts, 50 Amps @ 240 Volts | |
| Features: |
Totally Brushless Design with Capacitor All Copper Windings Voltage Plus, <6% Distortion Exclusive Smooth Wave Voltmeter Hour Meter Easy Idle with Delay Circuit Full Power Switch at 120 Volts & 240 Volts Circuit Breaker Protector for Each Receptacle Lifting Kit |
|
| Fuel Tank: | 8 U.S. Gallons | |
| Run Time: (Gasoline) |
1/2 Load = 6.9 Hours Full Load = 6.0 Hours |
|
| Engine: | 23 HP Vanguard, OHV, Twin Cylinder, Full
Pressure Lubrication, Oil Cooler and Oil Filter, Low Oil Pressure Shut
Down, Cast Iron Cylinder Liners, Electic Start with Auxiliary Recoil Starter and Low Tone Muffler |
|
| Receptacles: |
2-20amp, 120 Volt, GFI NEMA, 5-20R (4 Outlets
Total) 1-30amp, 120 Volt, Twistlock, NEMA L5-30R 1-30amp, 240 Volt, Twistlock, NEMA L14-30R 1-50amp, 120 Volt, Twistlock, CS6370 1-50amp, 240 Volt, Twistlock, CS6369 Main Line Circuit Breaker Plus Individual Plus Circuit Breaker Protector for Each Receptacle |
|
| Frame: | 1" Welded Steel Roll Cage Frame with Isolated Recessed Control Panel, Heavy Duty Vibration Isolators | |
|
Dimensions |
|||
| Length | Width | Height | Weight |
| 30" | 24" | 31" | 284 lbs. |
| 30000 Watt Tractor Driven PTO Generator | ||
| Model: | PTO30/25 | |
| Wattage: | 30000 Watts Surge, 25000 Watts Continuous, 1 phase, 60Hz @ 3600 RPM | |
| Amps: | 208 Amps @ 120 Volts, 104 Amps @ 240 Volts | |
| Features: |
Totally Brushless Design with Capacitor All Copper Windings Voltage Plus, <6%-9% Distortion Exclusive Smooth Wave Voltmeter Thermal/Magnetic Circuit Breakers PTO Safety Shield Lifting Eye Full Power 240 Volt Plugs/Connectors Included Gear Transmission |
|
| Minimum Required Engine HP: |
50 |
|
| Shaft Diameter: | 1-3/8" 6 Spline | |
| PTO RPM: | 540 | |
| Generator RPM: | 3600 | |
| Max Motor Starting, Code G: |
10 |
|
| Receptacles: |
1- 120 Volt, Duplex 20A, 5-20R 1-240 Volt, 30A, L14-30R Full Power Connector Circuit Breakers |
|
|
Dimensions |
|||
| Length | Width | Height | Weight |
| 36.5" | 15.75" | 16.75" | 330 lbs. |